What Your Inverter Error Code Means, by Brand
Inverter Error Codes are used by solar inverters to indicate faults or performance issues within your solar system. Each brand of inverter displays specific inverter error codes to help identify problems related to the inverter, grid connection, or other system components. Understanding inverter error codes early can prevent system downtime and costly repairs.
This page outlines the possible meanings of common inverter error codes across a range of inverter brands used in Australia. By recognising these inverter error codes, you can better diagnose faults and take the appropriate next steps to restore system performance.
When to Call a Professional For An Inverter Error
While some inverter error codes can be resolved with basic troubleshooting, others require expert diagnosis. Electrical systems can be hazardous; therefore, attempting complex repairs without proper training is not recommended.
For more detailed information on inverter error codes and troubleshooting methods, refer to your inverter’s user manual. If issues continue or become frequent, consult a licensed professional to ensure your system operates safely and efficiently.
General Inverter Troubleshooting Tips:
- Reset the inverter: Turn off the inverter, wait for a few minutes, and then turn it back on to see if the fault clears.
- Check grid conditions: Verify that the grid voltage and frequency are within the acceptable range. If there are grid issues, contact your utility provider.
- Inspect wiring and connections: Check both the DC and AC connections for loose or damaged wires. Ensure all connections are secure and free of corrosion.
- Ensure proper ventilation: Make sure the inverter is in a cool, well-ventilated area to prevent overheating. Clean any dust or debris around the inverter to allow proper airflow.
- Inspect solar panels: If the fault relates to DC voltage or the I-V curve, inspect the solar panels for damage, shading, or dirty surfaces, and check for proper wiring.
- Monitor inverter performance: Use the inverter monitoring system (if available) to track real-time data and logged faults.
- Check for firmware updates: Make sure the inverter is using the latest firmware. Sometimes issues are caused by outdated software.
- Consult the user manual: Refer to the inverter manual for more specific troubleshooting steps.
- Contact technical support: If the issue persists, contact your inverter brand customer support or a qualified technician for further assistance.
For more detailed information on fault codes and troubleshooting, refer to the inverter’s user manual. Please be aware that attempting to resolve these issues without electrical expertise can be hazardous and we recommend consulting with a licensed professional to resolve complex or recurring issues.
You can view different inverter brands below, then your fault codes inside toggle.
Pick your inverter brand below to find its error codes. If a code keeps coming back or won’t clear with a reset, we repair all of these brands. See the inverter brands we repair and replace.
Fronius Inverter Error Codes
The error codes listed include different and includes Fronius products, including the Fronius IG (a single-phase inverter with power categories from 1.5 to 5 kW), Primo, Symo and GALVO inverters.
Fronius Error Codes beginning with 1xx
A 1xx code is usually temporary, caused by the power from the electrical mains (grid) being outside the inverters operating parameters.
|
Error Code |
Description of Error |
What to Do |
|
STATE 101 |
Grid voltage beyond permitted limits. Caused by: 1. Mains voltage error 2. Incorrect values in the service menu 3. Internal fault |
1. Check grid voltage, check circuit breakers are ON. 2. Change values in the service menu. 3. If problem persists contact your Fronius Service Partner. |
|
STATE 104 |
Mains frequency beyond permitted limits. Caused by: 1. Mains frequency error 2. Incorrect values in the service menu 3. Internal fault |
1. Check mains frequency, check circuit breakers are ON. 2. Change values in the service menu. 3. If a problem persists, contact your Fronius Service Partner. |
|
STATE 107 |
Synchronisation with the public mains supply not possible. Caused by: 1. Mains not connected 2. Incorrect values in the service menu 3. Internal fault |
1. Connect mains power, check circuit breakers are ON. 2. Check values in the service menu. 3. If a problem persists, contact your Fronius Service Partner. |
|
STATE 108 |
Islanding detected. Caused by: 1. Islanding detected 2. Severe disturbances in public mains 3. Internal fault |
1. Automatic correction 2. If a problem persists, contact your Fronius Service Partner. |
Fronius Error Codes beginning with 2xx
A 2xx code is a message from the grid monitoring device (ENS) integrated within the inverter that refers to the parameters of the public mains.
|
Error Code |
Description of Error |
What to Do |
|
STATE 201 |
Grid voltage beyond permitted limits. Caused by: 1. Mains voltage error 2. Incorrect values in the service menu 3. Internal fault |
1. Check grid voltage, check circuit breakers are ON. 2. Change values in the service menu. 3. If a problem persists, contact your Fronius Service Partner. |
|
STATE 202 |
Grid voltage is lower than the specified limit. Caused by: 1. Grid voltage error on the public mains 2. Internal fault |
1. Check grid voltage. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 203 |
Grid frequency is higher than the specified limit. Caused by: 1. Grid frequency error on the public mains 2. Internal fault |
1. Check grid frequency. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 204 |
Grid frequency is lower than the specified limit. Caused by: 1. Grid frequency error on the public mains 2. Internal fault |
1. Check grid frequency. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 205 |
Change of public mains impedance. Caused by: 1. Serious disturbances on the public mains 2. Internal fault |
1. Reinforce mains cables. 2. Connect Fronius IG inverter to another phase. 3. If a problem persists, contact your Fronius Service Partner. |
|
STATE 206 |
Absolute value of the impedance is too high. Caused by: 1. Mains impedance too high 2. Internal fault |
1. Reinforce mains cables. 2. Connect Fronius IG inverter to another phase. 3. If a problem persists, contact your Fronius Service Partner. |
|
STATE 207 |
The Mains relay does not open in spite of the switch off signal. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 208 |
The Mains relay does not close in spite of the switch on signal. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
Fronius Error Codes beginning with 3xx
A 3xx code can occur during grid feed-in operation.
|
Error Code |
Description of Error |
What to Do |
|
STATE 301 |
Safety circuit detects a current peak on the mains supply. Caused by: 1. Voltage drop on the public mains 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 302 |
Safety circuit detects a current peak on the PV generator side. Caused by: 1. Voltage drop on the public mains supply 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 303 |
Heat sink temperature on the DC-AC board is too high. Caused by: 1. Ventilation slot congested 2. Very high ambient temperature 3. Distance between inverters too small 4. Internal fault |
1. Free ventilation slot. 2. Change location of inverter. 3. Increase distance between inverters. 4. If a problem persists, contact your Fronius Service Partner. |
|
STATE 304 |
Heat sink temperature on the DC-DC board is too high. Caused by: 1. Ventilation slot congested 2. Very high ambient temperature 3. Distance between inverters too small 4. Internal fault |
1. Free ventilation slot. 2. Change location of inverter. 3. Increase distance between inverters. 4. If a problem persists, contact your Fronius Service Partner. |
|
STATE 305 |
Feed-in process not possible, even though public mains parameter within the limits. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 306 |
POWER LOW. Caused by an intermediate circuit voltage has dropped below the permissible threshold value for feed in. |
1. Check panels. 2. Internal fault. |
|
STATE 307 |
DC LOW. Caused by: 1. DC-input voltage is too low for feed in 2. Internal fault |
1. Check panels. 2. Internal fault. |
|
STATE 308 |
Intermediate circuit voltage out of the maximum limit. Caused by: 1. Public mains disturbances 2. Internal fault |
1. Reinforce mains cable. 2. If a problem persists, contact your Fronius Service Partner. |
Fronius Error Codes beginning with 4xx
A 4xx error is triggered by faulty hardware or a software problem that requires the intervention of a Fronius Service Partner.
|
Error Code |
Description of Error |
What to Do |
|
STATE 401 |
Communication error between IG control and the DC-DC board. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 402 |
Write access to the internal Fronius IG memory failed. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 403 |
The area in the internal memory for the country setting is incomplete. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 404 |
Connection between the control unit and the ENS is faulty. Caused by: 1. Public mains not connected 2. Internal fault |
1. Check the public mains. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 405 |
An old or incorrect version of the ENS microprocessors has been recognised. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 406 |
Temperature sensor on the DC-AC board faulty or not connected. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 407 |
Temperature sensor on the DC-DC board faulty or not connected. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 408 |
Unsymmetry on the public mains detected. Caused by: 1. Public mains disturbances 2. Internal fault |
1. Error is remedied automatically. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 409 |
Supply of the DC-AC board is not available. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 410 |
Service plug on the DC-AC board is not set correctly. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 412 |
Value for the fixed voltage is set higher than the open circuit voltage of the PV generator. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 413 |
Open circuit voltage is too high at the moment of transformer switching. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 414 |
Memory array for Fronius IG type in EE-PROM faulty. Caused by: 1. One-off – memory error 2. Internal fault |
1. Error is remedied automatically. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 415 |
No END-enabling signal despite release by IG-control. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 416 |
Communication error between IG-Control and power stack. Caused by: 1. One-off – communication error 2. Internal fault |
1. Error is remedied automatically. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 419 |
Two or more power stacks with identical Unique ID. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 420 |
Incomplete number of power stacks detected after reaching online threshold according to device type. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 421 |
Hardware ID sequence error. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 425 |
Receive time-out for data exchange with one or more power stacks exceeded. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 431 |
All power stacks are in boot mode. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 432 |
Consistent error in power stack management. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 433 |
Allocation error of dynamic addresses. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 434 |
Ground fault detected. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 435 |
Wrong configuration for EE-Prom. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 436 |
Error transmission faulty. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 437 |
Power stack work around is active. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 438 |
Error during state code transmission. Caused by: 1. One off error 2. Permanent error |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 441 |
Power rack fan faulty. Caused by an internal fault |
If a problem persists, contact your Fronius Service Partner. |
|
STATE 442 |
Master for one phase could not be assigned. Caused by: 1. Temporary communication error 2. Internal fault |
1. Error is remedied automatically. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 443 |
DC-DC energy transfer failure. Caused by: 1. Error during switching on a power stack 2. Internal fault |
1. Error is remedied automatically. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 444 |
AC monitoring self test interrupted. During the self test another error occurred. |
Quit the self test by pressing ESC and remedy the failure according to the error code list. |
Fronius Error Codes beginning with 5xx
A 5xx code generally does not stop the feed-in operation, but will continue to show until the message is acknowledged by pushing a button on the display.
|
Error Code |
Description of Error |
What to Do |
|
STATE 501 |
Heat sink temperature too high, although Fronius IG is on low output. Caused by: 1. Ventilation slot congested 2. Internal fault |
1. Free ventilation slot. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 502 |
An isolation fault between DC+ or DC- to earth has been detected. Caused by isolation fault at the solar generator. |
Check cables and the solar generator. |
|
STATE 504 |
An error occurred while scanning LocalNet addresses. Caused by Identical Fronius IG address used twice. |
Check the address of the inverters and other components. |
|
STATE 505 |
The area in the internal memory for the “Setup” values is incomplete. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 506 |
The area in the internal memory for the “Total” values is incomplete. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 507 |
The area in the internal memory for the “Day/Year” values is incomplete. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 508 |
The area in the internal memory for the “WR number” is damaged. Caused by: 1. One off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 509 |
No feed in operation for 24 hours. Caused by: 1. Snow covered or very dirty solar panels. 2. Insufficient power from the solar panels for feed in operation. 3.Internal error. |
1. Clean solar panels or remove snow. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 510 |
Errors detected by LocalNet self diagnostic system. Caused by: 1. One-off memory error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 511 |
Errors detected by LocalNet Sensor Card self diagnostic system. Caused by: 1. One-off memory error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 512 |
According to the device type too many power stacks have been detected. Caused by: 1. One-off memory error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 513 |
Power stacks in boot mode. Caused by: 1. One-off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner |
|
STATE 514 |
Incomplete number of power stacks detected after reaching online threshold – Device type. Caused by: 1. One-off error 2. Internal fault |
1. Automatic correction. 2. If a problem persists, contact your Fronius Service Partner. |
|
STATE 515 |
One or more power stacks notified STATE 406/ 407/ 409/ 410. Caused by an internal fault. |
If a problem persists, contact your Fronius Service Partner. |
Fronius Error Codes beginning with 6xx
A 6xx error code indicates the necessary intervention by a Fronius trained service engineer or Fronius Service Partner.
Fronius Error Codes beginning with 7xx
A 7xx error code relates to the control system, the configuration and inverter data recording, and may directly or indirectly affect the process of feeding energy into the grid.
Error still showing after a restart? We do GoodWe inverter repairs across Melbourne.
F0 (Grid Fault)
Cause: The inverter detects a grid issue such as an overvoltage or undervoltage condition.
Action: Check the grid voltage and ensure it falls within the acceptable range. If the grid issue persists, contact the utility provider.
F1 (PV String Voltage Low)
Cause: The voltage from the solar panels (PV array) is too low.
Action: Check the wiring of the PV panels to ensure there are no faults. Ensure that the panels are connected properly and that there’s no shading or soiling.
F2 (DC Voltage High)
Cause: The DC input voltage is too high.
Action: Check for any issues with the DC side, like faulty wiring or a disconnected string.
F3 (AC Output Overcurrent)
Cause: The inverter is drawing more current from the AC grid than it is rated for.
Action: Verify the load connected to the inverter and check the AC circuit for any issues. Ensure that the inverter is not overloaded.
F4 (Inverter Overtemperature)
Cause: The inverter has overheated.
Action: Ensure the inverter is properly ventilated and that there are no obstructions around the cooling fan. Check for dirt buildup or issues in the cooling system.
F5 (Input DC Reverse Polarity)
Cause: The DC cables are connected with reverse polarity (positive and negative wires swapped).
Action: Disconnect the inverter from the power supply and correct the polarity of the cables.
F6 (AC Voltage Out of Range)
Cause: The AC grid voltage is outside the acceptable range.
Action: Check the grid voltage to ensure it’s within the allowed operating range. Contact your utility provider if needed.
F7 (Communication Fault)
Cause: The inverter is not communicating with the monitoring system.
Action: Check the communication cables and ensure that the inverter is correctly connected to the monitoring system.
F8 (Relay Fault)
Cause: A relay in the inverter has failed or there is an issue with the relay circuit.
Action: A service technician may be required to replace or repair the faulty relay.
F9 (Ground Fault)
Cause: The inverter detects a ground fault, which could indicate a problem with the wiring or the grounding of the system.
Action: Inspect the grounding system and check for any potential ground faults in the wiring.
Code won’t clear? Read about our SolarEdge inverter repair service.
Communication Lost Between Inverter and Internet
Description: Inverter cannot connect to monitoring servers.
Potential Causes: Network issues or server faults.
Fault coming back? See our Sungrow inverter repairs page.
Error 002-005: Grid Voltage Issues
Potential Causes: Grid instability or configuration errors.
Description: Grid voltage too high/low or transient faults.
Error 008-009: Grid Frequency Out of Range
Description: Grid frequency beyond acceptable range.
Potential Causes: Grid instability or incorrect settings.
System Fault Codes:
W01 – No Grid: Indicates no connection to the utility grid. Ensure the AC switch under the inverter and in the switchboard are turned on.
W02 – Vin Overvoltage: The voltage from the photovoltaic (PV) panels is too high. This is uncommon but may occur under certain conditions.
E01 – Isolation Error: Suggests water or moisture presence in the system, leading to insulation issues.
E02 – Ileak Error: Indicates a ground fault, often due to water or moisture.
E03 – Grid Fault: The grid voltage or frequency is out of the acceptable range. This should correct itself once the grid stabilizes.
Inverter Fault Codes:
E04 – Coherence Error: A general error indicating a malfunction within the inverter.
E05 – Over Temperature: The inverter has overheated. Ensure proper ventilation and consider reducing the load.
E06 – Relay Failure: The output relay has failed. This is typically a hardware issue requiring professional attention.
E07 – DC Injection Failure: The output current DC offset is too high, indicating a potential internal fault.
E08 – EEPROM Failure: The inverter’s EEPROM has failed, affecting its ability to store data.
E09 – Communication Failure: Indicates a communication issue, possibly with the monitoring system.
E10 – DC Bus Overvoltage: The DC bus voltage is too high, which can be dangerous.
E11 – DC Bus Undervoltage: The DC bus voltage is too low, affecting performance.
E12 – Vref Error: A reference voltage error, indicating a potential issue with the inverter’s internal components.
E13 – DC Sensor Fault: A fault with the DC voltage sensor, which may affect performance.
E14 – GFCI Failure: The Ground Fault Circuit Interrupter has failed, posing a safety risk.
For common faults and what we can fix, see Tesla inverter faults and repairs.
Error 101 – Grid Voltage Out of Range: The grid voltage is outside of the acceptable limits. This could be due to voltage surges or dips in the electrical grid.
Error 102 – Grid Frequency Out of Range: The grid frequency is either too high or too low. This could indicate issues with the utility grid.
Error 103 – AC Overload: The inverter is drawing more power than it can handle. This could happen if too many
appliances are connected to the inverter or the system is improperly sized.
Error 104 – AC Short Circuit: A short circuit is detected on the AC side of the system, which could be caused by faulty wiring or connections.
Error 105 – Overvoltage: The inverter is experiencing a voltage level that is higher than the safe operating limit for either the AC or DC side.
Error 106 – Undervoltage: The inverter detects a voltage drop below the acceptable limit, either on the AC or DC side.
Error 107 – High Temperature (Overheating): The inverter has overheated due to insufficient ventilation or prolonged operation in a hot environment.
Error 108 – Communication Failure: There is a failure in communication between the inverter and the monitoring system or other connected devices.
Error 109 – Isolation Fault: This error occurs when the inverter detects that the insulation resistance is too low, which could suggest a grounding issue or wiring fault.
Error 110 – DC Overvoltage: The DC voltage (from the solar array) exceeds the allowable limit, which can occur due to improper panel connections or malfunctioning components.
Error 111 – DC Undervoltage: The DC voltage is too low for the inverter to operate properly, possibly due to low sunlight or a damaged solar panel.
Error 112 – Grid Voltage Asymmetry: The voltage between phases is asymmetrical, which can cause imbalance issues in the inverter’s performance.
Error 113 – Ground Fault: The inverter has detected a fault in the grounding system, which could result from a short circuit or improper grounding of the system.
Error 114 – Internal Fault: This is a general internal error indicating a failure within the inverter’s internal components or circuitry.
Error 115 – Firmware Issue: The inverter’s firmware may have failed to load or operate correctly, requiring a software reset or update.
Error 116 – Inverter Start Failure: The inverter failed to start up properly. This may be due to an internal component failure or a system configuration issue.
Error 117 – Fan Failure: The cooling fan inside the inverter has stopped working, which could lead to overheating.
Error 118 – AC Output Voltage Fault: There is a fault with the output voltage from the inverter, which may indicate a malfunction with the inverter’s AC circuitry.
Error 119 – Ground Loop: This indicates a problem with a loop in the grounding system, which could cause performance or safety issues.
Error Code 1 – Battery temperature too high
This Error will auto-reset after the battery temperature has dropped. The charger will stop charging to prevent damaging the battery. The battery temperature can be received by an external sensor (like Smart Battery Sense or BMV), or measured by the charger when this feature is available.
Error Code 2 – Battery voltage too high
This Error will auto-reset after the battery voltage has dropped. This Error can be due to other charging equipment connected to the battery or a fault in the charge controller. This Error can also occur if the battery voltage (12, 24 48V) is set to a lower voltage than the connected battery.
Error Code 3, Error Code 4 – Remote temperature sensor failure
Check if the T-sense connector is properly connected to a remote temperature sensor. Most likely cause: the remote T-sense connector is connected to the BAT+ or BAT- terminal. This Error will auto-reset after proper connection.
Error Code 5 – Remote temperature sensor failure (connection lost)
Check if the T-sense connector is properly connected to a remote temperature sensor. This Error will not auto-reset.
Error Code 6, Error Code 7 – Remote battery voltage sense failure
Check if the V-sense connector is properly connected to the battery terminals. Most likely cause: the remote V-sense connector is connected in reverse polarity to the BAT+ or BAT- terminals.
Error Code 8 – Remote battery voltage sense failure (connection lost)
Check if the V-sense connector is properly connected to the battery terminals.
Error Code 11 – Battery high ripple voltage
High DC ripple is usually caused by loose DC cable connections and/or too thin DC wiring. After the inverter has switched off due to high DC ripple voltage, it waits 30 seconds and then restarts. After three restarts followed by a shutdown due to high DC ripple within 30 seconds of restarting, the inverter will shutdown and stops retrying. To restart the inverter, switch it Off and then On. Continuous high DC ripple reduces the inverter life expectancy
Error Code 14 – Battery low temperature
The charger is stopped to avoid charging LiFePO4 batteries at low temperature as this damages the cells.
Error Code 17 – Controller overheated despite reduced output current
This Error will auto-reset after charger has cooled down. Check the ambient temperature and check for obstructions near the heatsink.
Error Code 18 – Controller over-current
This Error will auto-reset. If the Error does not auto-reset disconnect the charge controller from all power-sources, wait 3 minutes, and power up again. Possible causes for an over-current on the battery terminals:
- switching on/off a very large load on the battery side.
- sudden change in irradiance causing a temporary over-power in the mppt.
- overloading the inverter ac output.
- Possible solutions:
- if possible provide adequate cooling for the unit, a cooler unit can handle more current.
- reduce the load on the inverter.
- charge the battery before using the inverter, at higher battery voltages the same amount of power requires less current.
Error Code 20 – Maximum Bulk-time exceeded
Solar Chargers
The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed.
If you do see this Error , then update to the latest firmware.
If you then still have the Error , perform a reset to factory defaults of the configuration, and reconfigure the solar charger.
AC Chargers
This protection is default enabled on the Skylla-i and the Skylla IP44.
This Error is generated when the battery-absorption-voltage is not reached after 10 hours of charging.
The feature of this safety protection is to detect a shorted cell; and stop charging.
Error Code 21 – Current sensor issue
The current measurement is out of range. Disconnect all wires, and then reconnect all wires, to make restart the charger. Also, make sure the minus on the MPPT charge controller (PV minus/Battery minus) is not bypassing the charge controller. This Error will not auto-reset. If the Error remains, please contact your dealer, there might be a hardware defect.
Error Code 22, Error Code 23 – Internal temperature sensor failure
The internal temperature measurements are out of range. Disconnect all wires, and then reconnect all wires, to restart the unit. This Error will not auto-reset. If the Error remains, please contact your dealer, there might be a hardware defect.
Error Code 24 – Fan failure
This Error indicates that the fan is powered on but the circuit does not measure any current draw by the fan. Most likely its either broken or obstructed.
Please contact your dealer, there might be a hardware defect.
Applies to Skylla-IP44 & Skylla-IP65 chargers only.
Error Code 26 – Terminal overheated
Power terminals overheated, check wiring, including the wiring type and type of strands, and/or fasten bolts if possible. This Error will auto-reset.
Error Code 27 – Charger short circuit
This condition indicates an over-current condition on the battery side. It can occur when a battery is attached to the unit using a contactor. Or in case the charger starts up without a battery connected but connected to an inverter that has a large input capacitance. This Error will auto-reset. If the Error does not auto-reset disconnect the charge controller from all power-sources, wait 3 minutes, and power up again. If the Error persists the charge controller is probably faulty.
Error Code 28 – Power stage issue
This Error will not auto-reset. Disconnect all wires, and then reconnect all wires. If the Error persists the charge controller is probably faulty. Note that this Error was introduced in v1.36. So when doing an update, it might look like the firmware update caused this issue; but it doesn’t. The Solar charger was then already not performing 100% before the update; updating to v1.36 or later merely made the issue more visible. The unit needs to be replaced.
Error Code 29 – Over-Charge protection
This Error will auto-reset once the battery voltage drops below the float voltage. To protect the battery from over-charging the battery is disconnected.
Possible causes:
- over-sized PV array configuration, if there are too many panels in series the battery voltage cannot be reduced any further. Consider wiring more PV panels in parallel to reduce the voltage.
- configuration issue, check if the battery settings match with the installation (especially absorption and float voltage settings).
- another charger in the system raises the battery voltage above the expected level.
Error Code 33 – PV over-voltage
This Error will auto-reset after PV-voltage has dropped to safe limit. This Error is an indication that the PV-array configuration with regard to open-circuit voltage is critical for this charger. Check configuration, and if required, re-organise panels.
Error Code 34 – PV over-current
The current from the solar-panel array has exceeded the rated current limit. This Error could be generated due to an internal system fault. Disconnect the charger from all power-sources, wait 3 minutes, and power-up again. If the Error persists the controller is probably faulty, contact your dealer.
Error Code 35 – PV over-power
Applies to the MPPT RS, Inverter RS and Multi RS products. Please upgrade your firmware to at least v1.08 as the issues causing this Error have been addressed. If you are using firmware v1.08 or newer this Error indicates that the internal dc voltage is too high. This Error will auto-reset. If the Error does not auto-reset disconnect the charge controller from all power-sources, wait 3 minutes, and power up again. If the Error persists the charge controller is probably faulty.
Error Code 38,
Error Code 39,
Error Code 80,
Error Code 81,
Error Code 82,
Error Code 83,
Error Code 84,
Error Code 85,
Error Code 86 and
Error Code 87 – PV Input shutdown
When these Errors show, the PV Input is internally shorted in order to protect the battery from over-charging. Prior to any other trouble shooting, make sure to update to the latest firmware version.
Possible reasons for this Error to occur:
- The Battery voltage (12/24/36/48V) is set incorrectly. Use VictronConnect to set the right Battery Voltage.
There is another device connected to the battery, which is configured to a higher voltage. For example a MultiPlus, configured to equalise at 17 Volts, while in the MPPT this is not configured. - Error recovery:
- Error 38 and Error s 84 to 87: First disconnect the solar panels and disconnect the battery. Wait for 3 minutes, then reconnect the battery first and next the panels.
- Error 39: The charger will automatically resume operation once the battery voltage drops below its maximum voltage setting (normally Equalisation or Absorption voltages). It can also takes a minute to reset the fault.
- Errors 80 to 83: First disconnect the solar panels and disconnect the battery, then follow the reset procedure described here.
If the Error persists the charge controller is probably faulty.
- The Battery voltage (12/24/36/48V) is set incorrectly. Use VictronConnect to set the right Battery Voltage.
Error Code 40 – PV Input failed to shutdown
If the charger is unable to turn off the PV input, it will go into a safe mode in order to protect the battery from over-charging or having a high voltage on the battery terminals. In order to do that, the charger will stop charging and disconnect its own output. The charger will become faulty.
Error Code 41 – Inverter shutdown (PV isolation)
PV panel isolation resistance too low. Check the PV array cabling and panel isolation, the inverter restarts automatically once the issue is resolved.
Error Code 42 – Inverter shutdown (PV isolation)
The ground leakage current in the PV array exceeds the allowed 30mA limit. Check the PV array cabling and panel isolation. Check the installation and restart the unit using the power-switch.
Error Code 43 – Inverter shutdown (Ground Fault)
The voltage difference between Neutral and Ground is too high.
Inverter or Multi (not connected to the grid):
- Inverter – The internal ground relay is activated but the voltage over the relay is too high. The relay might be damaged.
- Multi (connected to the grid):
- The ground wire in the installation is not present or not connected properly.
- Line and Neutral are swapped in the installation.
- This Error will not auto-reset. Check the installation and restart the unit using the power-switch.
Error Code 50, Error Code 52 – Inverter overload, Inverter peak current
Some loads like motors or pumps draw large inrush currents in a start-up situation. In such circumstances, it is possible that the start-up current exceeds the over current trip level of the inverter. In this case the output voltage will quickly decrease to limit the output current of the inverter. If the over current trip level is continuously exceeded, the inverter will shut down: wait 30 seconds and then restart. The Inverter can supply more power than the nominal power level for a short time. If the time is exceed the inverter stops. After three restarts followed by another overload within 30 seconds of restarting, the inverter will shutdown and remain off. To restart the inverter, switch it Off, then On. If the Error persists reduce the load on the AC out terminal by switching off or disconnecting appliances.
Error Code 51 – Inverter temperature too high
A high ambient temperature or enduring high load may result in shut down to over temperature. Reduce load and/or move inverter to better ventilated area and check for obstructions near the fan outlets. The inverter will restart after 30 seconds. The inverter will not stay off after multiple retries.
Error Code 53 – Inverter output voltage
If the battery voltage is getting low and a large load is applied to the AC output the inverter is unable to maintain the proper output voltage. Re-charge the battery or reduce the AC loads to continue operation.
Error Code 54 – Inverter output voltage
If the battery voltage is getting low and a large load is applied to the AC output the inverter is unable to maintain the proper output voltage. Re-charge the battery or reduce the AC loads to continue operation. If the Error immediately pops up when switching on the inverter (without load) on a full battery the cause is most likely a broken replaceable internal fuse. Contact your Victron dealer for support.
Error Code 55, Error Code 56, Error Code 58 – Inverter self test failed
The inverter performs diagnostic tests before it activates its output. In the case that one of these tests fails an Error message is displayed and the inverter does not turn on. First try to restart the inverter, by switching it Off, and then On. If Error persists the inverter is probably faulty.
Error Code 57 – Inverter ac voltage on output
There is already AC voltage on the AC out terminal before switching on the inverter. Check that the AC out is not connected to a mains outlet or to another inverter.
This Error will not auto-reset. Check the installation and restart the unit using the power-switch.
Error Code 59 – ACIN1 relay test fault
Automatic checking of the disconnect means failure. This usually indicates a broken relay (sticky contact) in the AC input stage.
Information 65 – Communication warning
Communication with one of the paralleled controllers was lost. To clear the warning, switch the controller off and back on
Information 66 – Incompatible device
The controller is being paralleled to another controller that has different settings and/or a different charge algorithm. Make sure all settings are the same and update firmware on all chargers to the latest version. This Error also appears if MPPTs are connected to a GX device while configured for a VE.Smart network. Disable the VE.Smart networking features and use DVCC on the GX instead. Further troubleshooting steps described here.
Error Code 67 – BMS Connection lost
This Error shows when the charger is configured to be controlled by a BMS, but does not receive any BMS control messages. In that situation, the charger stops charging by reducing its output voltage to the battery base voltage (12V/24V/36V/48V). This is a safety mechanism, the reason to still enable the output is to allow a system to self-recover from a battery low situation. Solar Chargers only show this Error when there is solar power available and thus the device is ready to initiate charging. It does not show at night. And in case there is a permanent problem, the Error will raise in the morning and clear at night, and so forth. Solution: check the connection between the charger and the BMS. How to reconfigure the charger to standalone mode Our Chargers and Solar Chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a GX Device. And that setting is semi-permanent: power cycling the charger will not reset it. When removing charger from such system, and reusing it in a system without BMS, that setting needs to be cleared. Here is how to do that:
- Chargers with LCD display: go into the setup menu, and change setting ‘BMS’ from ‘Y’ to ‘N’ (setup item 31).Other chargers: reset the charger to factory defaults with VictronConnect, and then reconfigure it.
Error Code 68 – Network misconfigured
Applies to SmartSolar/BlueSolar MPPTs VE.Can (FW version v1.04 or higher) and SmartSolar VE.Direct MPPTs (FW version v1.47).
To clear the Error on the SmartSolar VE – Direct MPPTs update the FW version to v1.48 or higher.
To clear the Error on the SmartSolar/BlueSolar MPPTs VE.Can – update the software. If the Error persists, it will be because the charger is connected with both a VE.Direct cable and on VE.Can. That is not supported. Remove one of the two cables. The Error will disappear and the charger will resume normal operation, within a minute.
Background: Error 68 indicates that the charger detects multiple conflicting network sources, with the same priority, trying to send the same information to the charger. VE.Can and VE.Direct interfaces have both the same priority level, and BLE (using VE.Smart Networking) has a lower priority. Having a higher priority level means that, if the same information (e.g. Battery voltage sense) is being received from both VE.Can and BLE (using VE.Smart Network) by the charger, the information on VE.Can will be used and the one coming from BLE will be ignored. Now, if the same information is being received from two interfaces that have the same priority level (as VE.Can and VE.Direct), the charger does not know how to prioritize those, causing Error 68 to be triggered.
Error Code 69 – Network misconfigured
Applies to Inverter RS and Multi RS models. Firmware versions 1.11 and higher.
This Error indicates an issue in the configuration. There are units present on the same can bus that have different system configurations. Please ensure that all units are set to either “Single Phase” or “Three Phase” and all units are set to either “50Hz” or “60Hz”. All units will remain off until the configuration is fixed, after which the units will resume operation.
Error Code 70 – Network misconfigured
Applies to Inverter RS models. Firmware versions 1.11 and higher.
Inverter RS units cannot be paired with a Multi RS and/or Transfer Switch.
Error Code 71 – Network misconfigured
Applies to Inverter RS and Multi RS models. Firmware versions 1.11 and higher. There are units present with incompatible firmware on the can bus. Make sure that all units are updated to the same firmware version. All units will remain off until the until the firmwares are updated, after which the units will resume operation.
Error Code 72 – Phase rotation
Applies to Inverter RS and Multi RS models. Firmware versions 1.12 and higher. Check the if the phase order is correct L1→L2→L3. The inverters remain operational, they won’t connect to the grid. Once the issue is resolved the units will connect.
Error Code 73 – Multiple AC inputs
Applies to Inverter RS and Multi RS models. Firmware versions 1.12 and higher. Per phase only one active connection to the grid is allowed, remove or switch off the redundant connection. The inverters remain operational, they won’t connect to the grid. Once the issue is resolved the units will connect.
Error Code 74 – Phase overload
Applies to Inverter RS and Multi RS models. Firmware versions 1.12 and higher. The number of inverters in parallel doesn’t match with the transfer capabilities of the ac input relay of the Multi RS or Transfer switch. Firmware v1.12 does not support parallel units and a grid connection, so any combination of a Multi RS with a grid connection with more than one unit in parallel will trigger this on the Multi RS. The Multi RS only supports 3 units in 3-phase configuration at the moment. The inverters remain operational, they won’t connect to the grid. Once the issue is resolved the units will connect.
Error Code 75 – Network misconfigured
Applies to Multi RS models. Firmware versions 1.19 and higher.
Three phase operation is not yet certified in combination with the selected grid code. The inverters remain operational, they won’t connect to the grid.
Error Code 114 – CPU temperature too high
This Error will reset after the CPU has cooled down. If the Error persists, check the ambient temperature and check for obstructions near the air inlet and outlet holes of the charger cabinet. Check manual for mounting instructions with regard to cooling. If Error persists the controller is probably faulty.
Error Code 116 – Calibration data lost
If the unit does not work and Error 116 pops up as the active Error the unit is faulty, contact your dealer for a replacement. If the Error is only present in the history data and the unit operates normally this Error can be ignored safely. Explanation: when the units power up for the very first time in the factory, it does not have calibration data and an Error 116 is logged. Obviously this should have been cleared, but in the beginning units left the factory with this message still in the history data. SmartSolar models (not the BlueSolar models): upgrading to v1.4x firmware is a one-way trip, you cannot go back to an older firmware version once you upgrade to v1.4x. Reverting to older firmware gives Error 116 (calibration data lost), this can be fixed by re-installing the v1.4x firmware.
Error Code 117 – Incompatible firmware
This Error indicates that a firmware update did not complete, so the device is only partially updated. Possible causes are: device out of range when updating over the air, a cable got disconnected or power was lost during the update session. To fix this the update needs to be retried, download the correct firmware for your device from the Victron Professional Portal. When your GX device is connected to VRM, you can do a remote firmware update using this firmware file. You can do this via the VRM website or using the VRM tab in VictronConnect. VictronConnect can also be used together with the firmware file to update using a Bluetooth connection. The procedure to add the file to VictronConnect and start the update is described here: 9. Firmware updates
Error Code 119 – Settings data lost
The charger cannot read its configuration, and stopped.
This Error will not auto-reset. To get it working again:
- First, restore it to factory defaults. (top right in Victron Connect, click on the three dots)
- Disconnect the charge controller from all power-sources
- wait 3 minutes, and power up again.
- Reconfigure the charger.
Please do report this to your Victron dealer and ask him to escalate it to Victron; as this Error should never happen. Preferably include firmware version and any other specifics (VRM URL, VictronConnect screenshots or similar).
Error Code 121 – Tester fail
If the unit does not work and Error 121 pops up as the active Error the unit is faulty, contact your dealer for a replacement. If the Error is only present in the history data and the unit operates normally this Error can be ignored safely. Explanation: when the units powers up for the very first time in the factory, it does not have calibration data and an Error 121 is logged. Obviously this should have been cleared, but in the beginning units left the factory with this message still in the history data.
Error Code 200 – Internal DC voltage Error
The unit performs internal diagnostics when activating its internal DC-DC converter. This Error indicates that something is wrong with the DC-DC converter. This Error will not auto-reset. Check the installation and restart the unit using the power-switch. If the Error persists the unit is probably faulty.
Error Code 201 – Internal DC voltage Error
Applies to the MPPT RS, Inverter RS and Multi RS. This “Internal DC voltage measurement Error ”, is raised in case an internal (high-) voltage measurement does not match certain criteria. First, make sure to update the firmware to v1.08 or later. The limits were too strict in earlier versions. And it could trigger falsely during MPPT start-up in the morning and MPPT shutdown in the evening. If the Error still occurs after updating to v1.08 or later, then it means that a measurement circuit inside the unit is broken. This Error will not auto-reset. Check the installation and restart the unit using the power-switch. If the Error persists, even after above mentioned firmware update, the unit is most likely faulty and must be sent in for repair/replacement.
Error Code 202 – Internal GFCI sensor Error
The sensor used to measure residual current did not pass the internal self test. This Error will not auto-reset. Check the installation and restart the unit using the power-switch. If the Error persists the unit is probably faulty and must be sent in for repair/replacement.
Error Code 203, Error Code 205, Error Code 212, Error Code 215 – Internal supply voltage Error.
The unit performs internal diagnostics when activating its internal voltage supplies. This Error indicates that something is wrong with an internal supply voltage. This Error will not auto-reset. Check the installation and restart the unit using the power-switch. If the Error persists the unit is probably faulty
E01 – Grid Voltage High: The grid voltage exceeds the maximum allowable range for the inverter.
E02 – Grid Voltage Low: The grid voltage is too low for the inverter to operate properly.
E03 – Grid Frequency High: The grid frequency is too high for the inverter to function.
E04 – Grid Frequency Low: The grid frequency is too low, preventing the inverter from working properly.
E05 – AC Overload: The inverter is overloaded on the AC side, meaning the power demand is higher than the inverter’s capacity.
E06 – AC Short Circuit: A short circuit has been detected on the AC side, possibly due to a wiring issue.
E07 – Overtemperature: The inverter has overheated, which may be caused by poor ventilation or excessive ambient temperature.
E08 – DC Overvoltage: The DC voltage from the solar panels exceeds the inverter’s maximum allowable input voltage.
E09 – DC Undervoltage: The DC input voltage is too low, which may affect the inverter’s ability to operate.
E10 – Ground Fault: A ground fault has been detected, which could indicate an issue with the grounding system or wiring.
E11 – Isolation Fault: The inverter has detected a fault with insulation resistance, which could be a sign of wiring issues or a short circuit.
E12 – I-V Curve Fault: The inverter detects an issue with the current-voltage (I-V) curve of the solar array, potentially indicating panel damage, shading, or wiring issues.
E13 – Communication Failure: The inverter is unable to communicate with the monitoring system or other connected devices.
E14 – Internal Fault: An internal fault has occurred within the inverter, possibly due to a malfunctioning component or circuitry.
E15 – Inverter Startup Failure: The inverter failed to start correctly, possibly due to a configuration error or an internal malfunction.
E16 – Fan Failure: The inverter’s cooling fan has failed, which can lead to overheating if not addressed.
E17 – Output Voltage Fault: There is an issue with the inverter’s output voltage, which could be caused by faulty internal components or grid connection issues.
E18 – High Ambient Temperature: The temperature around the inverter is too high, which could cause it to shut down to prevent overheating.
E19 – Communication Module Fault: A fault has occurred with the inverter’s communication module, preventing it from interacting with monitoring systems or other external devices.
E20 – GFCI Fault: The Ground Fault Circuit Interrupter (GFCI) has detected an issue, likely related to leakage current or ground faults.
Still getting the error? See our Zeversolar inverter repair page.
Error 3: Relay-Check Fault (Failed Output Relay) Description: Self-test detected a relay malfunction. Potential Causes: Defective output relay or control circuit issues. Error 34: Grid Voltage Outside Permitted Range (Vac Failure) Description: Grid voltage is beyond acceptable limits. Potential Causes: Grid instability or incorrect inverter settings. Error 35: Utility Loss Description: Grid is not detected. Potential Causes: Power outages, damaged cables, or blown fuses. Error 36: Residual Current Fault Description: Residual current exceeds the upper limit. Potential Causes: Insulation failures or grounding issues. Error 37: PV Overvoltage Description: Photovoltaic input voltage is too high. Potential Causes: Excessive solar panel output or configuration errors. Error 38: Isolation Failure Description: Low insulation resistance or electrical insulation failure detected. Potential Causes: Damaged cables or moisture ingress.